Put housing (1) flat on the ground making sure the large opening end is up.
Push the bearing (2) into the housing bore til it is connected well. Note of caution, Don’t try to beat the bearing into it’s proper place.
Place the housing on its side and put roll pin (3) thru the hole in the control cover pad. Then the roll pin needs to be put in 3/8″ below pad surface. Then put the two dowel pins (4) in the blind holes in the same pad.
Then on the other side of the housing…do these steps again.
Put the oring (5) and the plug (6) in the bottom of the housing. The roll pins (3) are in the bottom half of the housing.