Hi / Lo System – High Pressure Operation

Posted by Tammy Soper on

At our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:

 

Hi / Lo System – High Pressure Operation

When the work load is linked and work pressure is wanted, pump – electric motor pressure starts rising toward the relief valve setting of 1500 PSI. When it passes thru the 500 PSI pressure level, the normally closed unloading valve opens letting the 45 GPM pump to unload while the 5 GPM pump tries to work. This is taking place to eliminate unnecessary power generation by the 45 GPM pump when it is not needed.

 

Let us know if you have any questions or just would like to leave a comment.

You can call us at 800-361-0068

Email – sales@hydrostatic-transmission.com


Share this post



← Older Post Newer Post →


Leave a comment

Please note, comments must be approved before they are published.