Sundstrand Sauer Danfoss Series 90 Journal Bearings & Cylinder Block Install
Posted by Tammy Soper on
At our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:
Sundstrand Sauer Danfoss Series 90 Journal Bearings & Cylinder Block Install
If the bearing is put in the correct way, it will be .020 in. under the valve plate surface of the end cap.
When putting in a new journal bearing, the bearing needs to be proportionate to the arbor to give it the minimum bore diameter. Slowly press the sizing arbor into the bearing to measure it up exactly.
Squeeze the cylinder block spring and take out the spiral retaining ring, retainer, spring and spring seat.
Now flip this in reverse to put it back together.
If you need further assistance on this subject matter, please let us know.
call 800-361-0068
sales@hydrostatic-transmission.com