Sundstrand Sauer Danfoss Series 20 – Neutral Start Switch Replacement Part 2

Posted by Tammy Soper on

At our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss:

Sundstrand Sauer Danfoss Series 20 – Neutral Start Switch Replacement Part 2
Switch Adjustment
Be sure the control is in the neutral position. To check to see if it is in neutral you can see by rotating the control link assembly til the neutral start switch pin is immersed in the slot on the cam assembly.
Put a constant checker to the 2 screws on the end of the switch.
When the control is in the neutral position, turn it CCW til electrical continuity is acquired.
Turn switch CCW an extra 1/8 turn after continuity has been received.
Holding the switch in place with a wrench tighten the locknut with a another wrench.
With the checker on the switch, rotate the control lever in each direction to make sure continuity is broken when the control is not in the neutral position.

Call us if you have any questions, 800-361-0068
Email: sales@hydrostatic-transmission.com


Share this post



← Older Post Newer Post →


Leave a comment

Please note, comments must be approved before they are published.