Sundstrand Sauer Danfoss M46 Filter Adapter
Posted by Tammy Soper on
At our Hydrostatic Pump Repair Site, we offer many types of Hydrostatic
Transmission Repair and information relating to Hydrostatic Parts
Today we will discuss
Sundstrand Sauer Danfoss Series 40 M46
Minor Repairs and Replacement
Filter Adapters
To remove the filter adapter from the pump housing you take off three hex head screws with a 1/2″ wrench or three 12 point head screws with a 5/16″ wrench. Take off the Orings (earlier units) or gasket (later units).
The early production units use a filter adapter with two orings, later ones have three orings. Always change your orings.
On the earlier units, install orings in the grooves of the filter adapter. Then you can install the adapter onto the pump housing. The later units, install the spacer/gasket and adapter onto the housing.
Reinstall the screws and torque to 16 to 21 lbsf*ft (22 to 28 NM)
Call us anytime with questions or if you want a quote on a repair.
We will be glad to help you
800-361-0068
hydrostatic-transmission.com