Denison Goldcup Series M11 & M14 Control Cover Assy

Posted by Tammy Soper on

Denison Goldcup Series M11 & M14 Control Cover Assy

You will need lubricate orings (21,22) and put it in the counter bores and grooves in the covers (16,17).
Put the cover assemblies over the dowel pins on the housing pads and make sure they have seals (13) and screws (14). Torque it to 30 ft lbs.
Also the input cover assy needs to be put in on the right hand side of the housing on the motors with “B” suffix. Pu the output cover assy on the right side on the models with “A” suffix.
Port locations
Port Size Function
A & B 4 bolt pad for SAE 1 1/2″ system power
D SAE 16 STR. THD. Drain
D1 & D2 SAE 12 STR. THD. Alternate Drain
DG SAE 6 STR. THD. Case Pressure
H1 & H2 SAE 8 STR. THD. Control Pressure Intel

If you need questions answered about this, call us at800-361-0068
sales@hydrostatic-transmission.com


Share this post



← Older Post Newer Post →


Leave a comment

Please note, comments must be approved before they are published.